The system is composed of a receiving test table, a transmitting beacon, a PC, a control and acquisition system, a measurement instrument (vector network analyzer, spectrum analyzer, signal source), multi-channel coaxial switch, radio frequency transmission line and standard gain horn. Low noise amplifier, power amplifier, monitoring.
Indoor anechoic chamber the size of the quiet zone should cover
the antenna maximum size; the test distance should satisfy D = 2D2 / λ.
Install separate anti-static
grounding, lightning protection cannot be accessed, the grounding resistance
<3 ohms.
Equipment required 50Hz
single-phase 220-volt AC power supply, power> 10KW.